User’s ManUalversion 3.3LIT-0163 www.sensaphone.com
10SAT4D User’s Manual
11Chapter 1: IntroductionChapTer 1: inTrodUCTionCongratulations on your purchase of the SAT4D by Sensaphone.The SAT4D Satellite-based monitoring devic
12SAT4D User’s Manual• 4 Dry Contact Inputs configurable as Normally Open or Normally Closed• Alarm message delivery to 8 Voice telephone numbers and
13Chapter 2: InstallationChapTer 2: insTallaTionThe SAT4D consists of an Input board and Satellite transmitter mounted in a NEMA 4X enclosure. (See Fi
14SAT4D User’s Manualthe sky at up to a 45 degree angle in all directions. An optional pole kit is available for this purpose (Part # FGD-SAT4D-PKIT).
15Chapter 2: InstallationZONE INpUT WIRINGThe SAT4D has 4 Zone Inputs that are compatible with dry contact sensors/outputs configured as either Normal
16SAT4D User’s Manual 1 C ZONES 2 C 3 C 4 C ~ ~ ~ ~ Multiple normally-closed sensors wired in series (ex
17Chapter 2: InstallationCONFIGURING THE ALARM RECOGNITION TIMESet the Alarm Recognition Time for each zone input by setting the DIP Switches accordin
18SAT4D User’s ManualChapTer 3: sysTeM prograMMingThe SAT4D requires minimal programming which makes it very easy to use. Included with the device is
19Chapter 3: System ProgrammingIf you’d like to have alarm messages (SMS) sent to your cell phone, en-ter your telephone number along with the appropr
2SAT4D User’s ManualEvery effort has been made to ensure that the information in this document is complete, accurate and up-to-date. Sensaphone assume
20SAT4D User’s ManualChapTer 4: operaTionSATELLITE COMMUNICATION AND ALARMSWhen an alarm is detected the SAT4D will transmit the alarm message multipl
21Chapter 4: Operationtion, total number of messages transmitted, the present status (OK or Alarm), and the date/time of the last message sent. To vie
22SAT4D User’s ManualBATTERY INFORMATIONThe Satellite transmitter operates from (4) 1.5V AA lithium bat-teries which will last 3+ years. The Input boa
23Chapter 4: OperationNote that all e-mail and text messages will be sent out simultane-ously as soon as the alarm is received at the SAT4D website. V
24SAT4D User’s ManualpROGRAMMING CHANGESOn the SAT4D website, simply click on the link to “Edit Programming” from the top of the Map page and you can
25Appendix A: Test Procedureappendix a: TesT proCedUreWe recommend that you periodically test your Sensaphone SAT4D to be sure it is functioning prope
26SAT4D User’s Manualappendix b: aCCessoriesThe sensors listed below are available from Sensaphone and rep-resent the most commonly used devices. Othe
27Appendix C: Specificationsappendix C: speCifiCaTionsALERT ZONESNumber of Zones: 4Zone Connector: terminal blockZone Types: N.O./N.C. ContactZone Char
28SAT4D User’s ManualENVIRONMENTALOperating Temperature: -22° to 140°F (-30° to 60° C) Normal, -40° to 185°F (-40° to 85° C) with battery life impactp
29Appendix D: Returning the Unit for Repairappendix d: reTUrning The UniT for repairIn the event that the SAT4D does not function properly, we suggest
30SAT4D User’s Manualappendix e: TesT logAlarms
31Appendix E: Test LogAlarms
32SAT4D User’s Manual
4SAT4D User’s ManualHAZARDOUS LOCATION SAFETY REQUIREMENTSThis product has been tested and found to be compliant for use in Hazardous Locations define
5 FCC STATEMENTPart 15: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FC
6SAT4D User’s Manual1 YEAR LIMITED WARRANTYPLEASE READ THIS WARRANTY CAREFULLY BEFORE USING THE PRODUCT.THIS LIMITED WARRANTY CONTAINS SENSAPHONE’S ST
7 ARE INAPPLICABLE, THEN THE PURCHASER’S SOLE REMEDY SHALL BE PAYMENT TO THE PURCHASER OF THE ORIGINAL COST OF THE PRODUCT, AND IN NO EVENT SHALL WARR
8SAT4D User’s ManualWARRANTORS ASSUME NO LIABILITY FOR INSTALLATION OF THE PRODUCT AND/OR INTERRUPTIONS OF THE SERVICE DUE TO STRIKES, RIOTS, FLOODS,
9Table of ContentsTable of ConTenTsCHApTER 1: INTRODUCTION .....11SUMMARY OF FEATURES .........11TECHNICAL SUPPOR